___Site Index

 Back to Symptoms

 

DX 2517 SSB DISTORTION
  • SYMPTOM:
    • Excessive SSB receiver distortion
  • PROBLEM:
    • Unstable VCO drive signal at IC2 pin 5
  • SOLUTION:
    • Replace R121 with a 5.6K ohm 1/8 watt resistor